HomeIndexesTripp LitePDUMH15HVATNET

Tripp Lite PDU Switched ATS 2/2.4KW 200/240V 10 C13 2 C14 3.6M Cords 1URM

Tripp Lite PDUMH15HVATNET

Click image to enlarge or see more views.

Volume Discounts
Contact us and save even more if you meet these Big Deal qualifications.
Purchase a minimum of $10,000 of hardware, or $500 of cables to qualify.

Not enough in stock? No problem! We can ship your large quantity order direct from Tripp Lite's warehouse. These orders typically ship within 2-3 business days.


Model PDUMH15HVATNET

UPC Code: 037332197504

Provantage Code:  TRP93FL

Condition:  Factory New

  • Product Type: PDU
  • Plug/Connector Type: IEC 60320 C14
  • Mount Type: Rack-mountable
  • Input Voltage: 230 V AC
  • Country of Origin: Taiwan
  • TAA Compliant: Yes

TAA CompliantBig DealsSatisfaction Guaranteed

ComputingPower AccessoriesPower Distribution Units (PDU)

Specifications

Tripp Lite PDUMH15HVATNET Specifications

    Tripp Lite PDU Switched ATS 2/2.4KW 200/240V 10 C13 2 C14 3.6M Cords 1URM


Highlights


    Rear View
    Switched PDU systems can be accessed, configured and controlled through secure web, SNMP or Telnet Interface. Individually switched outlets can be controlled via a built-in web/network interface, enabling remote reboot of unresponsive network hardware. User defined power-up and power-down outlet sequences ensure proper operation of interdependent IT systems and prevent inrush-related overloads as devices are powered on.

At a Glance

    • Primary and Secondary Inputs for Power Redundancy
    • Provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations
    • Dual 3.6 m input cords with IEC-320 C14 plugs connect to separate primary and secondary single-phase power sources
    • 8 switched and 2 unswitched C13 outlets
    • Automatic Transfer Switching
    • Dynamic solid-state (TRIAC) automatic transfer switching
    • Switches to secondary power source if primary source fails or becomes unstable
    • 2-5 ms transfer time ensures uninterrupted operation of connected equipment
    • Built-in processor monitors both sources and prevents switching if secondary source is unavailable or of lower quality than primary source
    • Digital Load Meter

Overview


    Left View

    2-2.4kW Single-Phase ATS PDU with Primary and Secondary Inputs for Power Redundancy

    Recommended for data centers, server rooms and network closets, this 1U switched power distribution unit enables redundant A/B power for network devices with single power cords. Dual 12-foot (3.7-meter) input cords with C14 plugs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids. Plug-lock insert sleeves are included to prevent connected cords from becoming accidentally dislodged. The PDUMH15HVATNET constantly evaluates the power quality of both input sources and maintains continuous power to all outlets as derived from the primary source.

    Switches from Primary to Secondary Power Source in Milliseconds

    Dynamic solid-state automatic transfer switching (ATS) allows the IEC C13 PDU to switch to the secondary source within 2-5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor prevents switching if the secondary source is unavailable or of lower quality than the primary source.

    Switched C13 Outlets Are Individually Controllable for Remote Reboots and Load Shedding

    This switched power distribution unit distributes, monitors and manages selectable 200-240V power to equipment in network applications requiring individual outlet control, load shedding and remote monitoring of critical network components. Eight switched C13 outlets (two additional C13 outlets are unswitched) are subject to advanced network control and remote power monitoring, including the ability to turn on, turn off, reboot or lock out power to each outlet. Reducing the frequency of on-site visits can save you money and reduce downtime, thus lowering the PDU's total cost of ownership.

    Check Essential Functions at a Glance

    A front-panel digital load meter displays total PDU output current in amps. LEDs indicate on/off status of individual outlets and power status of primary and secondary inputs. An input-voltage select switch lets you toggle between high (220, 230 or 240V) or low (200 or 208V) voltage.

    Built-In LX Platform Interface Gives You Unrestricted Remote Access to Your Equipment 24/7

    The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.

    Reduce Service Calls with Auto Probe Autonomous Device Management

    The Auto Probe feature (Firmware 15.5.2 and greater) checks the connectivity status of any networked device and automatically takes one or more user-configured actions if the device fails to respond; actions include outlet reboot, set SNMP traps, SNMP OID sets, and even script execution when used in conjunction with the Tripp Lite PowerAlert Network Shutdown Agent (PANSA).

    Easy to Install Horizontally in an EIA-Standard 19 in. Rack

    This ATS PDU mounts in 1U of space in 19-inch rack or rack cabinet using the included brackets and hardware.

    TAA-Compliant for GSA Schedule Purchases

    The PDUMH15HVATNET is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

Management


    Front View

    • HTTP
    • HTTPSPowerAlert
    • SMTP
    • SNMPv1
    • SNMPv2
    • SNMPv3
    • Telnet
    • SSH
    • FTP
    • DHCP
    • BOOTP and NTP protocols

Package Contents

    • PDUMH15HVATNET 10-Outlet PDU
    • 10 x C14 plug lock inserts
    • 2 x C13 to C14 power cords, 3.6 m (11.8 ft.)
    • SNMPWEBCARD configuration cable
    • 2 x Mounting brackets, horizontal
    • 2 x Mounting brackets, vertical
    • 6 x Screws
    • Owner's manual


Specifications

Product NameTripp Lite PDU Switched ATS 2/2.4KW 200/240V 10 C13 2 C14 3.6M Cords 1URM
Product TypePDU
Receptacle TypeIEC 60320 C13
TAA CompliantYes
Mounting OrientationHorizontal
Power Rating (Watt)2400 W
Receptacle Detail10 x IEC 60320 C13
Rack Height1U/2U
Plug / Connector TypeIEC 60320 C14
Input Voltage Range200 V AC - 240 V AC
Input Current10 A
Mount TypeRack-mountable
Protection TypeOverload Protection
Input Voltage230 V AC
Output Voltage200 V AC

208 V AC

220 V AC

230 V AC

240 V AC

Environmentally FriendlyYes
Network (RJ-45)Yes
Plug / Connector Detail2 x IEC 60320 C14
Country of OriginTaiwan
Height1.7"
Width17.3"
Depth14.4"
Product ModelPDUMH15HVATNET
Packaged Quantity1
Limited Warranty2 Year
Supplies/Accessories for Tripp Lite PDUMH15HVATNET




Tripp Lite EnviroSense2 (E2) Environmental Sensor Module

Mfg Part# E2MTHDI



Considering a Volume Purchase?
You may be able to save even more on your order if you meet the following Tripp Lite BIG DEAL qualifications:

Purchase a minimum of $10,000 of hardware, or $500 of cables to qualify.

Not enough in stock? No problem! We can ship your large quantity order direct from Tripp Lite's warehouse. These orders typically ship within 2-3 business days.


Shop with confidence! Provantage is an authorized Tripp Lite dealer.

Visit the Manufacturer
Learn more by visiting the manufacturer's website.

Tripp Lite
 
© Copyright 1984-2024 Provantage
Tripp Lite Model PDUMH15HVATNET