Model PDUMH30HVATNET

UPC Code: 037332159601

Provantage Code:  TRP91U4

Condition:  Factory New

  • Product Type: PDU
  • Plug/Connector Type: NEMA L6-30P
  • Product Family: Switched
  • Input Voltage: 230 V AC
  • Country of Origin: Taiwan
  • TAA Compliant: Yes

TAA CompliantBig DealsSatisfaction Guaranteed

ComputingPower AccessoriesPower Distribution Units (PDU)

Tripp Lite PDUMH30HVATNET Specifications

    Tripp Lite PDU Switched ATS 208V / 240V 30A 16 C13; 2 C19; 1 L6-30R 2URM


Details

    Features Include
    • 208/240V 30A auto Transfer Switch / ATS in 2U horizontal rackmount installation format (agency de-rated to 24A continuous)
    • Separate primary and secondary L6-30P inputs, each with 10 ft. / 3m line cord
    • 19 switched output receptacles (16 C13, 2 C19 & 1 L6-30R)
    • Connected equipment is normally powered from the primary input; ATS circuit provides automatic transfer to the secondary power source input within 2-6 milliseconds if primary input power is interrupted
    • ATS functionality is available with any two compatible AC power sources, even configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported, regardless of phase angle
    • Advanced ATS setup options enable advanced UPS configurations, including hot-swappable UPS replacement and dual-UPS* protection (*dual-UPS configurations require the use of an online, double-conversion UPS on the primary input, such as Tripp Lite's SmartOnline series)
    • Built-in SNMP/Web network interface offers remote control and monitoring options
    • Offers the ability to turn on, turn off, recycle and lock-out power to each individual receptacle and remotely monitor output power consumption per-phase or per-outlet via email, secure web, SNMP or Telnet interface
    • Real-time power control enables real-time remote-reboot of unresponsive network hardware or to power-off unnecessary network hardware
    • Programmable power control can enable user-defined power-up, power-down outlet sequences to ensure proper operation of interdependent IT systems, prevent inrush-related overloads as network equipment is first energized or lock-out power to unused PDU outlets to prevent powering of unauthorized network hardware
    • Outlets are factory programmed for sequential turn-on at 250 millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction on startup
    • Lighted display with scroll-button offers numeric power consumption data in amps for all 3 loading banks, IP-address and self-identification
    • Built-in SNMP/ethernet interface reports voltage, frequency and PDU loading information via network or secure web browser interface
    • Supports logging of all power events with user specified alarm and notification thresholds for load levels and site voltage conditions
    • Supports in-rack environmental and security monitoring for advanced configurations with optional ENVIROSENSE temperature / humidity probe and rack access notification for up to 4 SRSWITCH door sensors or other user-supplied contact-closure sensors
    • DHCP/Manual configuration support provides the ability to have network settings automatically assigned to the card, or manually assigned a static IP addresses
    • 10/100 Mbps auto-sensing allows optimal communication compatibility with your current 10/100 Base-T network
    • Real-time clock backup maintains the time of day and date even if the PDU is shut down and unpowered
    • Tiered access privileges allow an administrator and a guest to log into the web browser for monitoring all PDUs
    • Alert notifications via email or SNMP traps give users the added advantage of having an immediate event notification
    • Firmware upgradeability supports future product enhancements
    • Protocols supported include HTTP, HTTPS, PowerAlert network Management System, SMTP, SNMPv1, SNMPv2, Telnet, SSH, FTP, DHCP, BOOTP, NTP
    • Fully compatible with PowerAlert network Management system / NMS Software, available via FREE download from www.tripplite.com
    • Included cord retention brackets keep vital network equipment plugged in and continuously powered

    In the box

    • 2U ATS PDU
    • Rackmount installation brackets
    • Cable retention plates
    • 18 cable ties
    • User manual

At a Glance

    • Single phase 30A 208/240V Auto Transfer Switch / ATS PDU with Solid State Switching
    • Separate primary & secondary inputs enable redundant-power option for non-redundant network devices
    • LX Platform Network Interface
    • 2U rackmount, 2 L6-30P inputs, 19 switched outlets (16 C13, 2 C19, 1 L6-30R)
    • Individually switched outlets, network interface and visual current, voltage and environmental monitoring
    • Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases

Overview

    Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Highly reliable solid-state switching between primary and secondary inputs occurs in 1-5 milliseconds. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability. Built-in LX Platform network management interface card. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.

Management

    Protocols:

    • HTTP
    • HTTPS
    • PowerAlert Network Management System
    • SMTP
    • SNMPv1
    • SNMPv2
    • Telnet
    • SSH
    • FTP
    • DHCP
    • BOOTP
    • NTP

Additional Product Images


Specifications

Product NameTripp Lite PDU Switched ATS 208V / 240V 30A 16 C13; 2 C19; 1 L6-30R 2URM
Product TypePDU
Receptacle TypeNEMA L6-30R

IEC 60320 C19

IEC 60320 C13

Product FamilySwitched
TAA CompliantYes
PDU TypeSwitched
Mounting OrientationHorizontal
Receptacle Detail1 x NEMA L6-30R

2 x IEC 60320 C19

16 x IEC 60320 C13

Rack Height2U
Plug / Connector TypeNEMA L6-30P
Mount TypeRack-mountable
Input Voltage230 V AC
Environmentally FriendlyYes
Plug / Connector Detail2 x NEMA L6-30P
Country of OriginTaiwan
Product SeriesSwitched
Product ModelPDUMH30HVATNET
Limited Warranty2 Year
Supplies/Accessories for Tripp Lite PDUMH30HVATNET






The Following Product is Compatible With Tripp Lite PDUMH30HVATNET

Considering a Volume Purchase?
You may be able to save even more on your order if you meet the following Tripp Lite BIG DEAL qualifications:

Purchase a minimum of $10,000 of hardware, or $500 of cables to qualify.

Not enough in stock? No problem! We can ship your large quantity order direct from Tripp Lite's warehouse. These orders typically ship within 2-3 business days.


Shop with confidence! Provantage is an authorized Tripp Lite dealer.

Visit the Manufacturer
Learn more by visiting the manufacturer's website.

Tripp Lite
 
© Copyright 1984-2024 Provantage
Tripp Lite Model PDUMH30HVATNET