HomeIndexesServer TechnologyC2WG24SN-YBLN5D6

Server Technology Switched Master PRO2 Pops Pips, 2U, 24 Hdot Outlets (18XC13,6XCX), Input Amp Meters

Server Technology Power Distribution Units (PDU)

Image may not be actual.


Model C2WG24SN-YBLN5D6

Provantage Code:  SETE2RF

Condition:  Factory New

  • Product Type: PDU
  • Plug/Connector Type: NEMA L21-20P
  • Input Current: 20 A
  • Product Family: PRO2
  • PDU Type: Switched

Satisfaction Guaranteed

ComputingPower AccessoriesPower Distribution Units (PDU)

Specifications

Server Technology C2WG24SN-YBLN5D6 Specifications

    Switched Master PRO2 Pops Pips,2U,24 Hdot Outlets(18XC13,6XCX) ,Input Amp Meters,208V 3-Phase 20A,NEMA L21-20P,10 Ft


At a Glance

    • HDOT Cx Outlets
    • Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
    • Network Monitoring
    • Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
    • Hot-Swap Network Card
    • Network access is ensured when power is lost to the Primary unit with backup power provided by the Linked unit.
    • Star Multi-Linking
    • PRO2 provides the ability to link up to four power circuits using one IP address. Primary Expansion PDU provides backup power to network card.
    • Temperature/Humidity Monitoring
    • Primary and Expansion (select products) units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.
    • IP Access, Security & Communications
    • Web, SSH, Telnet, SNMPv2c & v3, RS-232 serial, 10/100 Base T-Ethernet, LDAP(S), TACACS+, RADIUS, DHCP, & SMTP/email.
    • Auto-Flip Current Display
    • Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.
    • Per-Inlet Power Sensing
    • PIPS® (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
    • Per-Outlet Power Sensing
    • POPS® (Per Outlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.
    • Branch Current Monitoring
    • Monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
    • Branch Circuit Protection
    • This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
    • Outlet Control
    • On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.
    • High Retention Locking Outlets
    • PRO2 receptacles have high retention and are compatible with P-Lock type power cords.
    • Color-Coded Options
    • Select from six colors to designate PDU circuits in the data center - black, white, red, green, blue, and yellow.

Overview

    The Server Technology® PRO2 Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® and POPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Switched POPS "Primary" PDU can be connected to as many as three (with optional module) PRO2 Switched POPS "Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.

Management

    • HTTP/HTTPS
    • TLSv1.2
    • SSHv2
    • Telnet
    • SNMPv2c
    • Syslog
    • v3 (GET, SET, Traps)
    • IPv4
    • IPv6
    • LDAPv3/LDAPS
    • TACACS+
    • RADIUS
    • FTP/SFTP
    • RS-232


Specifications

Product NameSwitched Master PRO2 Pops Pips, 2U, 24 Hdot Outlets (18XC13,6XCX), Input Amp Meters
Product TypePDU
PhaseThree Phase
Receptacle TypeIEC 60320 C13

CX

Product FamilyPRO2
PDU TypeSwitched
Power Rating (Watt)5700 W
Environmental SensorsTemperature/Humidity
Plug / Connector TypeNEMA L21-20P
Form FactorHot-swappable
Input Current20 A
Mount TypeRack-mountable

Cabinet-mountable

Protection TypeBranch Circuit

Double Pole

Circuit Protection

Input Voltage230 V AC
Output Voltage208 V AC
Network (RJ-45)Yes
Receptacle Detail18 x IEC 60320 C13

6 x CX

Height3.5"
Width17.2"
Depth17.5"
Product SeriesPRO2
Product ModelC2WG24SN-YBLN5D6
Limited Warranty2 Year
WARNING: Products made with PVC can expose you to chemicals including DEHP, which is known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Considering a Volume Purchase?

Shop with confidence! Provantage is an authorized Server Technology dealer.

Visit the Manufacturer
Learn more by visiting the manufacturer's website.

 
© Copyright 1984-2024 Provantage
Server Technology Model C2WG24SN-YBLN5D6