HomeIndexesServer TechnologyC2WG48TE-DQME2M99

Server Technology Switched Pops Master PRO2 (48) Configurable Alt Phase Hdot Outlets, 208V 3PH

Server Technology Power Distribution Units (PDU)

Image may not be actual.


Series PRO2

Manufacturer Part#  C2WG48TE-DQME2M99

Provantage Code:  SETE287

Condition:  Factory New

  • Product Type: PDU
  • Plug/Connector Type: IEC 60309 3P+G 9Hr 60A
  • Input Current: 60 A
  • Product Family: PRO2
  • PDU Type: Switched

Satisfaction Guaranteed

ComputingPower AccessoriesPower Distribution Units (PDU)

Specifications

Server Technology C2WG48TE-DQME2M99 Specifications

    Switched Pops Master PRO2 (48) Configurable Alt Phase Hdot Outlets, 208V 3PH Delta 6BR 60A 60309 3P+Pe 3M/10FT Cord, Auto-Orient Mid Display, Bottom Base Cord Entry, Doghouse Breakers, Phase Monitoring, LXWXD = 80.0X2.20X2.50 In. (2032X56X6)


At a Glance

    • HDOT Cx: Cx is the future ready UL tested hybrid of the C13 and C19 outlets accommodating both C20 and C14 plugs.
    • Network Monitoring: Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
    • Hot-Swap Network Card: Network access is ensured when power is lost to the primary unit with backup power provided by the primary link unit.
    • Star Multi-Linking: Provides the ability to link up to four power circuits using one IP address. Primary link provides backup power to network card.
    • Temperature/Humidity Monitoring: Primary and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications.
    • Auto-Flip Current Display: Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.
    • Per- Inlet Power Sensing: Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy.
    • Branch Current Monitoring: Monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
    • Branch Circuit Protection: This PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.
    • Outlet Control: On Switched rack PDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power off unused receptacles.
    • Alternating-Phase Outlets: Evenly distributes multiple phases of power to each outlet for simplified load balancing, reduced cord lengths, and better airflow.
    • High Temperature Rating: This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
    • Flexible Mounting: Includes standard button mounts along with provisions for custom mounting brackets.
    • Color Identification: Choose from six colors to designate circuits for rack PDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black.

Overview

    The Server Technology® PRO2 Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® and POPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Switched POPS "Primary" PDU can be connected to as many as three (with optional module) PRO2 Switched POPS "Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.

Application/Usage

    IT Equipment

    Server Rack/Cabinet

Management

    • HTTP/HTTPS
    • TLSv1.2
    • SSHv2
    • Telnet
    • SNMPv2c
    • v3 (GET, SET, Traps)
    • IPv4 and IPv6
    • LDAPv3/LDAPS
    • TACACS+
    • RADIUS
    • FTP/SFTP

Certifications & Standards

    Safety (Listed & Certified, cTUVus mark):

    • UL 62368-1
    • CSA C22.2 No. 62368-1

    EMC:

    • FCC Part 15 Subpart B Sections 15.107 & 15.109, Class A
    • CANICES-003, Class A

Package Contents

    • PRO2 48-Outlets PDU
    • Standard Button Mounts


Specifications

Product NameSwitched Pops Master PRO2 (48) Configurable Alt Phase Hdot Outlets, 208V 3PH
Manufacturer Part NumberC2WG48TE-DQME2M99
Product TypePDU
PhaseThree Phase
Receptacle TypeIEC 60320 C13

CX

Product FamilyPRO2
PDU TypeSwitched
Remote Outlet SwitchingYes
Power Rating (Watt)17.30 kW
Receptacle Detail30 x IEC 60320 C13

18 x CX

Plug / Connector TypeIEC 60309 3P+G 9Hr 60A
FeaturesLED Display
Input Current60 A
Mount TypeRack-mountable

Cabinet-mountable

Button Mount

Protection TypeBranch Circuit

Circuit Protection

Fuse

Input Voltage230 V AC
Output Voltage208 V AC
Input Frequency60 Hz
Minimum Operating Temperature32°F (0°C)
Maximum Operating Temperature140°F (60°C)
Minimum Storage Temperature-40°F (-40°C)
Maximum Storage Temperature185°F (85°C)
Network (RJ-45)Yes
Minimum Operating Humidity8%
Maximum Operating Humidity90%
Height80"
Width2.2"
Depth2.5"
Product SeriesPRO2
Limited Warranty2 Year
Circuit BreakerYes
WARNING: Products made with PVC can expose you to chemicals including DEHP, which is known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Considering a Volume Purchase?

Shop with confidence! Provantage is an authorized Server Technology dealer.

Visit the Manufacturer
Learn more by visiting the manufacturer's website.

 
© Copyright 1984-2024 Provantage
Server Technology Series PRO2 C2WG48TE-DQME2M99