HomeIndexesServer TechnologyC4G36RA-DFBD2FE1

Server Technology Switched Pops CS8365 3P+G 50A 12 C13+24 CX 208-240V 3-Phase 50A

Server Technology C4G36RA-DFBD2FE1

Series PRO4X

Manufacturer Part#  C4G36RA-DFBD2FE1

Provantage Code:  RAR98LP

Condition:  Factory New

  • Product Type: PDU
  • Limited Warranty: 2 Year
  • Product Family: PRO4X
  • Input Voltage: 230 V AC
  • Maximum Operating Temperature: 140°F (60°C)

Satisfaction Guaranteed

ComputingInput DevicesKVM Switches

Specifications

Server Technology C4G36RA-DFBD2FE1 Specifications

    Switched Pops CS8365 3P+G 50A 12 C13+24 CX 208-240V 3-Phase 50A


At a Glance

    • HDOT Cx Outlets: Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
    • 45 Degree Angled Infeed: The angled infeed improves accessibility, provides infeed strain relief, and its bend radius is suitable with 60A rated cords.
    • Network Monitoring: Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
    • Multi-Unit Linking & Cascading: Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.
    • Multi-Color LCD: An easy-to-read LCD provides a local indication of power usage, alerts, and alarms.
    • Hot Swappable Controller: The Controller is the PDU's center of intelligence and houses computing, display, and connectivity ports.
    • Power Quality Measurements: Monitor and alert on the power being fed to the PDU for harmonics, voltage dips and swells, crest factor, and more at the outlet or load.
    • RGB LED Outlet Indicators: RGB LEDs identify an outlet's on/off state, if it's above/below a certain power threshold, or if it's in suspect of a power measurement irregularity.
    • Waveform Capture: Capture voltage and current waveforms automatically or upon demand.
    • RamLock Locking Outlets: A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.
    • Environmental Monitoring: Support up to 12 daisy-chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.
    • Per-Inlet Power Sensing: PIPS® (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
    • Branch Circuit Protection: This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
    • Outlet Control: On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.
    • Alternating-Phase Outlets: Evenly distributes multiple phases of power to each outlet for simplified load balancing, reduced cord lengths, and better airflow.
    • High Temperature Rating: This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
    • Flexible Mounting: Includes standard button mounts along with provisions for custom mounting brackets.
    • Color-Coded Options: Select from six colors to designate PDU circuits in the data center - black, white, red, green, blue, and yellow.

Overview

    Server Technology's PRO4X Switched PDUs run on our state-of-the-art Xerus network interface platformand provide remote access to power, PDU status, input and branch current monitoring, and outlet on/off control. The PDU features RamLock, a self-locking mechanismto prevent accidental cord disconnects, and our award-winning HDOT Cx outlets that can be deployed as either a C13 or C19. Switched PDUs are secured with strong configurable password, active directory, 256-bit AES encryption, SSH, SSL and HTTPS support. SNMP traps provide automated alerts on power and environmental conditions fromLegrand's plug-and-play environmental monitoring sensors like temperature, humidity, water, dry contact closure, airflow, air pressure differential, and more.

Management

    • HTTP/HTTPS
    • TLSv1.2
    • SSHv2
    • Telnet
    • SNMPv2c
    • v3 (GET, SET, Traps)
    • IPv4 and IPv6
    • LDAPv3/LDAPS
    • TACACS+
    • RADIUS
    • FTP/SFTP

Certifications & Standards

    Safety (Listed & Certified, cTUVus mark):

    • UL 62368-1
    • CSA C22.2 No. 62368-1

    EMC:

    • FCC Part 15 Subpart B Sections 15.107 & 15.109, Class A
    • CANICES-003, Class A

Package Contents

    • PRO4X 36-Outlets PDU
    • Button Mounts


Specifications

Product NameSwitched Pops CS8365 3P+G 50A 12 C13+24 CX 208-240V 3-Phase 50A
Manufacturer Part NumberC4G36RA-DFBD2FE1
Product TypePDU
PhaseThree Phase
Receptacle TypeIEC 60320 C13

CX

Product FamilyPRO4X
PDU TypeSwitched
Remote Outlet SwitchingYes
Power Rating (Watt)14.40 kW
Locking ReceptaclesRamLock Locking Outlet
Receptacle Detail12 x IEC 60320 C13

24 x CX

Plug / Connector TypeCS8365 3P+G 50A
FeaturesMulti-color LCD
Input Current50 A
Mount TypeButton Mount
Protection TypeBranch Circuit

Circuit Protection

Circuit Breaker

Fuse

Input Voltage230 V AC
Output Voltage208 V AC
Input Frequency60 Hz
Minimum Operating Temperature32°F (0°C)
Maximum Operating Temperature140°F (60°C)
Minimum Storage Temperature-40°F (-40°C)
Maximum Storage Temperature185°F (85°C)
Network (RJ-45)Yes
Minimum Operating Humidity5%
Maximum Operating Humidity90%
Height70"
Width2.2"
Depth2.5"
Product SeriesPRO4X
Application / UsageIT Equipment
Limited Warranty2 Year
Circuit BreakerYes
Considering a Volume Purchase?

Shop with confidence! Provantage is an authorized Server Technology dealer.

Visit the Manufacturer
Learn more by visiting the manufacturer's website.

 
© Copyright 1984-2024 Provantage
Server Technology Series PRO4X C4G36RA-DFBD2FE1