HomeIndexesTripp LitePDUMH30HVAT

Tripp Lite PDU Metered ATS 208V / 240V 30A 16 C13; 2 C19; 1 L6-30R 2URM

Tripp Lite PDUMH30HVAT

Click image to enlarge or see more views.

Volume Discounts
Contact us and save even more if you meet these Big Deal qualifications.
Purchase a minimum of $10,000 of hardware, or $500 of cables to qualify.

Not enough in stock? No problem! We can ship your large quantity order direct from Tripp Lite's warehouse. These orders typically ship within 2-3 business days.


Model PDUMH30HVAT

UPC Code: 037332159212

Provantage Code:  TRP91TQ

Condition:  Factory New

  • Product Type: PDU
  • Plug/Connector Type: NEMA L6-30P
  • Product Family: Metered
  • Input Voltage: 230 V AC
  • Country of Origin: Taiwan
  • TAA Compliant: Yes

TAA CompliantBig DealsSatisfaction Guaranteed

ComputingPower AccessoriesPower Distribution Units (PDU)

Specifications

Tripp Lite PDUMH30HVAT Specifications

    Tripp Lite PDU Metered ATS 208V / 240V 30A 16 C13; 2 C19; 1 L6-30R 2URM


Summary


    Rear View
    PDUMH30HVAT Metered ATS / Auto-Transfer Switch offers 208/240V 30A dual-input power distribution and visual current metering in a 2U horizontal rackmount installation format. Set of two NEMA L6-30P line cords enable separate primary and secondary input connections. Includes 19 built-in outputs (16 C13, 2 C19 & 1 L6-30R). Digital current metering with push-button display control tracks output power consumption in 4 segments: Bank 1 (9 upper C13 & C19 outlets), Bank 2 (9 lower C13 & C19 outlets), L6-30R (single outlet) and total PDU output. Supports 2U installation in 2 or 4 post racks, with additional support for wall-mount and under-counter placement.

    Tripp Lites Metered ATS / Auto-Transfer Switch PDU systems provide redundant-power and hot-swappable UPS options for network and server applications powered by a single input line cord. Separate PRIMARY and SECONDARY input line cords enable a redundant connection to two separate mains circuits. ATS systems will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Super-fast switchover between primary and secondary power sources occurs within 2-6 milliseconds. ATS functionality is supported by any two compatible power sources, regardless of phase angle, to offer support for a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant dual-UPS protection when each cord is connected to a separate UPS system. In a dual-UPS configuration, the primary input cable must be supported by a full time sine wave online UPS. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LEDs display primary and secondary power availability. Additional LEDs identify the displayed load segment reported by the digital current display.

    Features Include

    • PDUMH30HVAT Metered ATS / Auto-Transfer Switch PDU offers 208/240V 30A dual-input power distribution and visual current metering in a 2U horizontal rackmount installation format (Agency de-rated to 24A continuous)
    • Set of two 10 ft. / 3m NEMA L6-30P input line cords enable separate PRIMARY and SECONDARY input connections
    • Includes 19 built-in outputs (16 C13, 2 C19 and 1 NEMA L6-30R)
    • Digital current metering with push-button display control and indicator LEDs tracks output power consumption in 4 segments: Bank 1 (9 upper C13 & C19 outlets), Bank 2 (9 lower C13 & C19 outlets), L6-30R (single outlet) and total output of all three load banks combined
    • Metered ATS PDU systems provide redundant power and hot-swappable UPS options for networking and server applications powered by a single input line cord
    • Separate primary and secondary input line cords enable connection to two separate mains circuits
    • The ATS PDU normally maintains continuous output to all outlets as derived from the primary input cable
    • If the primary input becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable
    • Super-fast switchover between primary and secondary power sources occurs within 2-6 milliseconds
    • ATS functionality is supported by any two 208/240V 30A power sources, regardless of phase angle, to offer reliable support for advanced redundant power networking applications
    • Enables fault-tolerant hot-swappable UPS protection when used with a single UPS and fully redundant dual-UPS protection when each cord is connected to a separate UPS system
    • In a dual-UPS configuration, the primary input cable must be supported by a full time sine wave online UPS. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application
    • ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported
    • On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
    • Front input LEDs display primary and secondary power availability; Additional LEDs identify the displayed load segment reported by the digital current display

    In the box

    • Auto Transfer Switch PDU
    • Rackmount installation brackets
    • Installable plug-retention shelves & cable ties

Details

    Features Include
    • PDUMH30HVAT Metered ATS / Auto-Transfer Switch PDU offers 208/240V 30A dual-input power distribution and visual current metering in a 2U horizontal rackmount installation format (Agency de-rated to 24A continuous)
    • Set of two 10 ft. / 3m NEMA L6-30P input line cords enable separate PRIMARY and SECONDARY input connections
    • Includes 19 built-in outputs (16 C13, 2 C19 and 1 NEMA L6-30R)
    • Digital current metering with push-button display control and indicator LEDs tracks output power consumption in 4 segments: Bank 1 (9 upper C13 & C19 outlets), Bank 2 (9 lower C13 & C19 outlets), L6-30R (single outlet) and total output of all three load banks combined
    • Metered ATS PDU systems provide redundant power and hot-swappable UPS options for networking and server applications powered by a single input line cord
    • Separate primary and secondary input line cords enable connection to two separate mains circuits
    • The ATS PDU normally maintains continuous output to all outlets as derived from the primary input cable
    • If the primary input becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable
    • Super-fast switchover between primary and secondary power sources occurs within 2-6 milliseconds
    • ATS functionality is supported by any two 208/240V 30A power sources, regardless of phase angle, to offer reliable support for advanced redundant power networking applications
    • Enables fault-tolerant hot-swappable UPS protection when used with a single UPS and fully redundant dual-UPS protection when each cord is connected to a separate UPS system
    • In a dual-UPS configuration, the primary input cable must be supported by a full time sine wave online UPS. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application
    • ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported
    • On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
    • Front input LEDs display primary and secondary power availability; Additional LEDs identify the displayed load segment reported by the digital current display
    • TAA-Compliant

    In the box

    • Auto Transfer Switch PDU
    • Rackmount installation brackets
    • Installable plug-retention shelves & cable ties

At a Glance

    • Single phase 30A 208V Auto Transfer Switch / ATS Metered PDU with Solid State Switching
    • Enables redundant-power configurations for single-corded network devices
    • Separate primary & secondary inputs connect to any two compatible power sources
    • 2U horizontal rackmount; 2 L6-30P inputs; 19 outlets (16 C13, 2 C19, 1 L6-30R)

Additional Product Images


Specifications

Product NameTripp Lite PDU Metered ATS 208V / 240V 30A 16 C13; 2 C19; 1 L6-30R 2URM
Product TypePDU
Receptacle TypeNEMA L6-30R

IEC 60320 C19

IEC 60320 C13

Product FamilyMetered
TAA CompliantYes
Mounting OrientationHorizontal
Receptacle Detail1 x NEMA L6-30R

2 x IEC 60320 C19

16 x IEC 60320 C13

Rack Height2U
Plug / Connector TypeNEMA L6-30P
Input Voltage Range208 V AC - 240 V AC
Mount TypeRack-mountable
Input Voltage230 V AC
Output Voltage208 V AC

240 V AC

Environmentally FriendlyYes
Plug / Connector Detail2 x NEMA L6-30P
Country of OriginTaiwan
Height3.5"
Width17.5"
Depth12.5"
Product SeriesMetered
Product ModelPDUMH30HVAT
Package Contents
  • Metered PDUMH30HVAT 19-Outlets PDU
  • Rackmount Installation Brackets
  • Installable Plug-retention Shelves
  • Cable Ties
Limited Warranty2 Year
Number of Cord / Cable2
Supplies/Accessories for Tripp Lite PDUMH30HVAT






Considering a Volume Purchase?
You may be able to save even more on your order if you meet the following Tripp Lite BIG DEAL qualifications:

Purchase a minimum of $10,000 of hardware, or $500 of cables to qualify.

Not enough in stock? No problem! We can ship your large quantity order direct from Tripp Lite's warehouse. These orders typically ship within 2-3 business days.


Shop with confidence! Provantage is an authorized Tripp Lite dealer.

Visit the Manufacturer
Learn more by visiting the manufacturer's website.

Tripp Lite
 
© Copyright 1984-2024 Provantage
Tripp Lite Model PDUMH30HVAT