HomeIndexesTripp LiteSU10000RT3U

Tripp Lite SmartOnline 10kVA UPS Rack/Tower PureSine 10KVA 200-240V 6-Outlet

Tripp Lite SU10000RT3U

Click image to enlarge or see more views.


Tripp Lite

SmartOnline Model SU10000RT3U

UPC Code: 037332127372

Provantage Code:  TRPL1KE

  • Product Type: Dual Conversion Online UPS
  • Load Capacity (VA): 10 kVA
  • Load Capacity (Watt): 8 kW
  • Backup/Run Time (Full Load): 6 Minute
  • Backup/Run Time (Half Load): 12 Minute

100% Satisfaction Guaranteed

ComputingPower Equipment / AccessoriesUPS - Industrial

Tripp Lite SU10000RT3U Specifications

    SmartOnline 10kVA UPS Rack/Tower PureSine 10KVA 200-240V 6-Outlet


Summary

    10,000VA (10kVA) on-line, double-conversion UPS system for critical server, network and telecommunications equipment. Installs in only 6 rack spaces (3U power module and 3U battery pack); maximum installed rack depth of 32.5 in. Expandable battery runtime with optional BP192V12-3U external battery packs. Full-time sine wave 200, 208, 220, 230, or 240V +/-2% output. Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 156V and overvoltages to 276V. Standard 3-wire 208V hardwire input connection; NEMA L6-30R and L6-20R output receptacles. Detachable input-output PDU module with manual bypass switch enables hot-swap UPS replacement without disrupting power to connected equipment. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces support simultaneous communications via RS-232, contact-closure port and optional SNMPWEBCARD slot. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Front panel LEDs offer at-a-glance confirmation of line power status, battery power status, AC-to-DC conversion, DC-to-AC conversion, bypass mode and output power status. Detailed LCD panel with scroll buttons offer detailed diagnostic test information at startup and during self tests, plus real-time data on input and output voltage, frequency (Hz), load percentage and battery charge level. Audible alarm. Self-test. Fault-tolerant auto-bypass mode. 4-post rackmount accessories and 2-9USTAND tower kit included. 2POSTRMKITWM 2-post rackmount hardware accessories available. Field replaceable, hot-swappable power module and external battery packs. Attractive all-black color scheme. 2-year warranty and$250,000 connected equipment insurance; extended warranty and service contracts available.

Details

    Features Include
    • 10,000VA (10kVA) on-line, double-conversion UPS system (High voltage input / High voltage output)
    • Detachable input-output PDU module with manual bypass switch enables hot-swap UPS replacement without powering off connected equipment
    • Installs in only 6 rack spaces (3U power module / 3U battery pack) with a maximum installed depth of 32.5 inches
    • Offers 6 minutes runtime at full load (10,000VA / 8000 watts) and 12 minutes at half load (5000VA / 4000 watts). Runtime is expandable with any number of optional BP240V10RT3U external battery packs
    • Full time sine wave 200, 208, 220, 230, or 240V +/-2% output (user selectable)
    • Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output
    • Operates continuously without using battery power during brownouts to 156V and overvoltages to 276V
    • Standard 3-wire 208V hardwire input connection
    • Two NEMA L6-30R and Two L6-20R output receptacles
    • Detailed LCD panel with scroll buttons offers detailed diagnostic test information on startup and during self tests, plus real-time data on input and output voltage, frequency (Hz), load percentage, battery charge level and more
    • Network-grade AC surge and noise suppression
    • Zero transfer time between AC and battery operation
    • Network management interfaces support simultaneous communications via RS-232, contact-closure port and optional SNMPWEBCARD slot
    • Supports detailed monitoring of equipment load levels, self-test data and mains power conditions via all 3 network interfaces at once. Includes PowerAlert monitoring software and complete cabling
    • Emergency Power Off (EPO) interface
    • Front panel LEDs offer at-a-glance confirmation of line power status, battery power status, AC-to-DC & DC-to-AC conversion, bypass mode and output power status
    • Fault-tolerant auto-bypass mode prevents loss of output during UPS fault conditions or excessive UPS loading
    • 4 post rackmount and upright tower installation accessories included. 2POSTRMKITWM two post rackmount hardware accessories available
    • Field replaceable, hot swappable power module and external battery packs
    • Attractive all-black UPS design
    • Two year warranty with $250,000 connected equipment insurance
    • Extended warranty and service contracts available

    In the box

    • 3U power module with detachable hot-swap PDU input/output panel and bypass switch
    • 3U external battery pack
    • Two sets of 4 post rackmount rails (one for each of the 3U components)
    • One set of tower stands for upright tower configuration
    • PowerAlert software, complete data cabling, user manual with warranty information

Overview

    Tripp Lite SU10000RT3U 10,000VA / 10kVA / 9000 watt online, double-conversion UPS system offers complete power protection for critical network applications. This system delivers online, double-conversion UPS protection with zero transfer time, suitable for advanced networking applications. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included detachable PDU with manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to connected equipment. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.

Specifications

General Information
Product NameSmartOnline 10kVA UPS Rck/Twr PureSine 10KVA 200-240V 6-Outlet
Product LineSmartOnline
Product ModelSU10000RT3U
Product TypeDual Conversion Online UPS
Technical Information
Plug / Connector TypeHardwired
Receptacles2 x NEMA L6-30R

4 x NEMA L6-20R

Battery Information
Backup / Run Time (Full Load)6 Minute
Backup / Run Time (Half Load)12 Minute
Management
Network ManagementSNMP Manageable
Power Description
Load Capacity (VA)10 kVA
Load Capacity (Watt)8 kW
Input Voltage220 V AC
Output Voltage200 V AC

220 V AC

208 V AC

230 V AC

240 V AC

Physical Characteristics
Form FactorTower/Rack Mountable
Warranty
Limited Warranty2 Year
Miscellaneous
Package Contents
  • Smart Online, SU10000RT3U, Expandable 10kVA Tower/Rack- mountable UPS System
  • 3U power module with detachable hot-swap PDU input/output panel and bypass switch
  • 3U external battery pack
  • Two sets of 4-post rackmount rails (one for each of the 3U components)
  • One set of tower stands for upright tower con
Other Information
Product FamilySmartOnline
Maximum Battery Recharge Time8 Hour
Maximum Operating Temperature104°F (40°C)
ColorBlack
AlarmBackup Operation

Low Battery

Output Overload

Inverter Fault

DC Bus Fault

Over Temperature

Remote Shutdown

Shutdown Complete

UPS Start

Imminent Shutdown

Bypass SwitchManual
Certifications & StandardsTested to UL1778 (USA), CSA (Canada), CE (European Union), NOM (Mexico), Class A (Emissions)
Rack Height6U
Emergency Power OFFYes
Frequency50 Hz

60 Hz

Switching Time0 ns
Thermal Dissipation3022 BTU/h
Waveform TypeSine Wave
Software IncludedPowerAlert Software
Additional Information
  • Switches: Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions
  • Low voltage transfer to battery power: Maintains continuous operation during undervoltages as low as 156VAC, below this point, output is maintained utilizing battery reserves
  • High voltage transfer to battery power: Maintains continuous operation during overvoltages to 276V AC, above this point, output is maintained utilizing battery reserves
  • Cold Start: Yes, inverter can be "cold started" to enable temporary AC output during a power failure
  • Voltage regulation description: On-line, double-conversion process give this UPS the ability to maintain output voltage within +/-2% of selected nominal voltage at all times
Supplies/Accessories for Tripp Lite SU10000RT3U


Tripp Lite 2 Port Rack Mount Kit 3U & Larger-UPS Trans Battery Pack

Mfg Part# 2POSTRMKITHD





Considering a Volume Purchase?
You may be able to save even more on your order if you meet the following Tripp Lite BIG DEAL qualifications:

Purchase a minimum of $1,500 for hardware, or $750 for cables.

Not enough in stock? No problem! We can ship your large quantity order direct from Tripp Lite's warehouse. These orders typically ship within 2-3 business days.


Shop with confidence! Provantage is an authorized Tripp Lite dealer.

Visit the Manufacturer
Learn more by visiting the manufacturer's website.

Tripp Lite
 
© Copyright 1984-2015 Provantage